{"count":61,"message":"Results returned successfully","results":[{"odiNumber":11013487,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/07/2017","dateComplaintFiled":"08/07/2017","vin":"2FTHF36G9NC","components":"FUEL/PROPULSION SYSTEM","summary":"TL* THE CONTACT OWNS A 1992 FORD F-350. WHILE FUELING THE VEHICLE, THE FUEL WAS TRANSFERRING TO THE REAR FUEL TANK AND OVERFLOWING. THE FAILURE CAUSED FUEL TO LEAK OUT ONTO THE GROUND. THE VEHICLE WAS TAKEN TO KALISPELL FORD, IN KALISPELL MT 59901, BUT THE RECALL HAD EXPIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE AND INFORMED THE CONTACT THAT THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 93V125000 (FUEL SYSTEM, GASOLINE). THE APPROXIMATE FAILURE MILEAGE WAS 130,000.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":10166902,"manufacturer":"Ford Motor Company","crash":true,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"07/26/2006","dateComplaintFiled":"08/22/2006","vin":"","components":"STEERING","summary":"1992 FORD F-350 HAD EQUIPMENT FAILURE, CAUSING IT TO STRIKE THE MEDIAN WALL. *KB  THE CONSUMER STATED A FAILURE WITHIN THE STEERING CAUSED THE ACCIDENT. *JB","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":10072197,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"04/29/2004","dateComplaintFiled":"06/04/2004","vin":"2FTJW35H2NC","components":"FUEL SYSTEM, GASOLINE","summary":"THE DEFECTIVE CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK.  WHEN THIS OCCURS, THE CAPACITY OF THE  SECOND TANK CAN BE EXCEEDED,  CAUSING FUEL SPILL.   SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO THE SOURCE OF IGNITION.  *AK  THE CONSUMER CONTACTED THE DEALER WHO INDICATED THAT THE RECALL HAD EXPIRED AND THAT THEY WOULD NOT FIX IT UNDER THE RECALL.  *NM","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":10033755,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"02/15/2003","dateComplaintFiled":"08/12/2003","vin":"","components":"FUEL SYSTEM, OTHER","summary":"CONSUMER STATES THAT VEHICLE IS LEAKING FUEL. DEALER NOTIFIED.*AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":10009252,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"02/24/2003","dateComplaintFiled":"02/25/2003","vin":"PLEASE PROV","components":"FUEL SYSTEM, GASOLINE","summary":"FUEL LEAKED OUT OF THE FRONT TANK.*JB","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":8021726,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/06/2001","dateComplaintFiled":"10/28/2002","vin":"1FDKF38G6NN","components":"FUEL SYSTEM, GASOLINE","summary":"CONSUMER STATES THAT WHEN  THEY HAD RECALL DONE, DEALERSHIP FORGOT TO INSTALL A PART STATED IN THE RECALL. WHICH CAUSE RECALL REDEEM TO FAIL. WENT BACK, THEY CORRECTED THE PROBLEM, BUT LATER ON PROBLEM REACCURED.      TS","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":764288,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/30/2002","dateComplaintFiled":"07/15/2002","vin":"","components":"TIRES","summary":"VEHICLE BEING TOWED BEHIND MOTORHOME ON I-29 NORTH OF ST.JOSEPH,MO. HEARD NOISE AND SAW SMOKE AND MOTORHOME BEGAN DRIFTING TO RIGHT.   AFTER STOPPING TO INVESTIGATE FOUND LEFT FRONT TIRE BLOWN OFF WHEEL,BRAKE LINE SEVERED, RUNNING BOARD MISSING AND CONSIDERABLE DAMAGE TO LEFT DOOR AND FENDER.  PUT ON SPARE THEN PROCEEDED TO PALMYRA, NE. FOR THE EVENING.  JUST AFTER CROSSING IN TO WYOMING THE NEXT DAY ANOTHER LOUD REPORT AND THE LEFT REAR TIRE BLEW OUT.  SAME TYPE OF TIRE AND SAME MILEAGE AS THE FRONT, ONLY THE BELT HAD WRAPPED AROUND THE AXLE AND LOCKED UP THE WHEEL. I HAVE THIS TIRE, WHAT IS LEFT OF IT ANYWAY.  CONDITIONS ON BOTH OCCURANCES: CLEAR WEATHER, TEMPS IN THE MID TO HIGH 80 S, SPEED WAS 65 MPH, TRAFFIC MODERATE.  TIRES WERE CHECKED AND INFLATED TO 50 PSI PRIOR TO DEPARTING BARTLETT, TN.  TREAD WAS ABOUT 50% ON ALL FOUR TIRES OF THE MATCHED SET. IF VEHICLE HAD BEEN DRIVEN INSTEAD OF BEING TOWED, THIS COULD HAVE BEEN DANGEROUS TO OCCUPENTS AND OTHER MOTORISTS IN BOTH INCIDENTS .*AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":751310,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"01/01/1999","dateComplaintFiled":"08/28/2001","vin":"","components":"TIRES","summary":"TIRES SEPARATED AT THE BEAD JOINT ON EACH TIRE AFTER ONLY 3,000 TO 5,000 MILES.  EXPLODED THROUGH THE TREAD CAUSING DAMAGE TO VEHICLE.  HAVE USED THESE TIRES FOR YEARS WITHOUT MISHAP UNTIL ABOUT TWO YEARS AGO.  PROBLEM STARTED ABOUT TWO YEARS AGO. CONCERNED ABOUT THE SAFETY OF THESE TIRES ON OTHER LESS STABLE VEHICLES.*AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":746134,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"05/20/2001","dateComplaintFiled":"05/30/2001","vin":"1FDKF37M2NN","components":"TIRES","summary":"THIS IS THE FOURTH TIRE FAILURE OF ORIGINAL EQUIPMENT TIRES SINCE NOV 2000.  *AK (DOT NUMBER: VNOP 65C  TIRESIZE: LT215/85)","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":884733,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"03/30/2001","vin":"1FTHF36GXNN","components":"FUEL SYSTEM, GASOLINE","summary":"WHEN FILLING FUEL TANK, ONE TANK WOULD OVERFLOW INTO  OTHER TANK AND CAUSE A SPILLAGE FROM THAT TANK. FUEL TANK REPAIRED UNDER RECALL  A SECOND TIME AS GOODWILL GESTURE.  CURRENTLY,  SERVICE MANAGER REFUSING TO DO  REPAIRS AGAIN. 2ND OWNER.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":877747,"manufacturer":"Ford Motor Company","crash":false,"fire":true,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"01/09/2001","vin":"","components":"ELECTRICAL SYSTEM","summary":"SHORTLY AFTER CHANGING  BATTERY  A FIRE IGNITED IN  DASH AREA, CAUSE UNKNOWN.  PLEASE GIVE ANY FUTHER DETAILS.*AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":733047,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"09/13/1996","dateComplaintFiled":"10/01/2000","vin":"2FTJW35G7NC","components":"TIRES","summary":"ONE TIRE FAILURE WAS DETECTED AS A LARGE BUBBLE  WHERE THE TREAD SEPARATED. THE SECOND WAS A COMPLETE LOSS OF TREAD. (TIRESIZE: LT235/85R1)( DOT NUMBER:   TIRE SIZE: LT235/85R1 )","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":730115,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/13/2000","dateComplaintFiled":"09/04/2000","vin":"1FTJX35M5NK","components":"TIRES","summary":"FRONT TIRES PUT ON BY DEALER WHEN I BOUGHT IT 03/03/2000 ON 06/13/2000 RIGHT FRONT TIRE  BEGAN TO JUMP UP AND DOWN AND SHAKE THE ENTIRE  TRUCK. TIRE STORE STATED  PROBLEM WAS DUE TO POSSIBLE BELT SEPERATION WITH-IN THE TIRE. I DID NOT REPLACE THEM WITH THE SAME BRAND TIRES. I HAVE NOT REPLACED THE REAR TIRES YET. FRONT ALIGNMENT WAS CHECK AND DETERMINDED NOT TO BE A FACTOR IN THE TIRE  FAILURE.( DOT NUMBER:   TIRE SIZE: LT-225-16 )","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":730115,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/13/2000","dateComplaintFiled":"09/04/2000","vin":"1FTJX35M5NK","components":"TIRES","summary":"FRONT TIRES PUT ON BY DEALER WHEN I BOUGHT IT 03/03/2000 ON 06/13/2000 RIGHT FRONT TIRE  BEGAN TO JUMP UP AND DOWN AND SHAKE THE ENTIRE  TRUCK. TIRE STORE STATED  PROBLEM WAS DUE TO POSSIBLE BELT SEPERATION WITH-IN THE TIRE. I DID NOT REPLACE THEM WITH THE SAME BRAND TIRES. I HAVE NOT REPLACED THE REAR TIRES YET. FRONT ALIGNMENT WAS CHECK AND DETERMINDED NOT TO BE A FACTOR IN THE TIRE  FAILURE.( DOT NUMBER:   TIRE SIZE: LT-225-16 )","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":859680,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"07/04/1999","dateComplaintFiled":"04/04/2000","vin":"2FTJW35M1NC","components":"ENGINE AND ENGINE COOLING","summary":"CONSUMER HAD A WATER PUMP PUT ON AT THE DEALERS. ON THE WAY HOME IN THE MIDDLE OF TRAFFIC, FAN BELT CAME OFF,  RESULTING IN NO STEERING AND BRAKES. CONSUMER FELT THIS WAS DANGEROUS SINCE VEHICLE LOST FAN BELT FIVE TIMES  EARLIER. TOOK VEHICLE TO DEALER, AND HAD TO PAY FOR BELTS.  DEALER SAID THERE WAS A PROBLEM WITH BELTS ON THESE VEHICLES.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":550593,"manufacturer":"Ford Motor Company","crash":false,"fire":true,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"12/17/1999","dateComplaintFiled":"01/28/2000","vin":"","components":"POWER TRAIN","summary":"TRANSMISSION FIRE, DUE TO POSSIBLE FAILURE.  *MJS","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":712506,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"09/20/1999","dateComplaintFiled":"09/29/1999","vin":"2FTJW35MXNC","components":"POWER TRAIN","summary":"HAVE HAD TO REPLACE COMPLETE CLUTCH ASSEMBLY THREE TIMES.   HAD THE SAME PROBLEM ON ON PREVIOUS FORD TRUCK.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":847453,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/03/1999","dateComplaintFiled":"09/10/1999","vin":"FILL IN","components":"FUEL SYSTEM, GASOLINE","summary":"THE VEHICLE HAD BEEN LEAKING FUEL FROM FRONT FUEL TANK. HAD TAKEN VEHICLE TO MECHANIC & WAS INFORMED THE TANK HAD RUSTED & NEEDED REPLACING.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":843743,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"07/26/1996","dateComplaintFiled":"07/29/1999","vin":"","components":"ENGINE AND ENGINE COOLING","summary":"THERE ARE  TWO TANK'S VALVES BETWEEN THE TANKS. WHEN  PUTTING GAS INTO ONE TANK, THE GAS WILL GO INTO THE OTHER TANK,  CAUSING A LEAK.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":708718,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"07/11/1999","dateComplaintFiled":"07/17/1999","vin":"3FCMF53G2NJ","components":"SUSPENSION,ENGINE AND ENGINE COOLING,FUEL SYSTEM, GASOLINE,POWER TRAIN,EXTERIOR LIGHTING","summary":"HERS IS A LIST OF ALL FAILURES SINCE NEW.  REAR AXEL SEALS, SWAY BAR BRACKETS, CATALYTIC CONVERTER, ECM MODULE, FRONT SEAL ON TRANSMISSION, FUEL PUMP, SPEEDOMETER (TWICE), TURN SIGNAL SWITCH, WATER PUMP AND NOW STARTING TO LEAK AGAIN. *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":544685,"manufacturer":"Ford Motor Company","crash":false,"fire":true,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/23/1998","dateComplaintFiled":"03/29/1999","vin":"","components":"FUEL SYSTEM, GASOLINE","summary":"TIRE DEBRIS SEVERED THE FILLER NECK REGION OF VEHICLE CAUSING GASOLINE TO SPILL ON ROADWAY AND COME INTO CONTACT WITH THE UNDERCARRIAGE WHICH RESULTED IN FIRE.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":829677,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"10/22/1998","dateComplaintFiled":"10/28/1998","vin":"2FDKF38G4CA","components":"SERVICE BRAKES, HYDRAULIC","summary":"WHEN APPLYING THE BRAKES THE PEDAL GOES TO THE FLOOR AND VEHICLE DOES NOT STOP. OWNER HAS TO DOWNSHIFT AND USE EMERGENCY BRAKE TO STOP. BRAKE CALIPERS HAD TO BE RPLACED AND DEFECT STILL EXISTS. DEFECT MAINLY OCCURS ON DECLINES.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":542282,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":1,"dateOfIncident":null,"dateComplaintFiled":"10/27/1998","vin":"","components":"PARKING BRAKE","summary":"PARKING BRAKE FAILURE RESULTING IN DISENGAGMENT AND DEATH WHEN VEHICLE ROLLED OVER CHILD.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":828587,"manufacturer":"Ford Motor Company","crash":false,"fire":true,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/23/1998","dateComplaintFiled":"10/05/1998","vin":"2FTJW35G4NC","components":"STRUCTURE,TIRES","summary":"TIRE  EXPLODED, CAUSING THE GAS TANK TO IGNITE,  AND  TRUCK TO BURNED COMPLETELY UP, BOAT THAT WAS TOWED WAS BURNED ALSO.  DESIGN OF THE VEHICLE SHOULD PROVIDE ADEQUATE SHIELD TO PROTECT FROM THIS OCCURRANCE. .*AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":541653,"manufacturer":"Ford Motor Company","crash":false,"fire":true,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/23/1998","dateComplaintFiled":"09/24/1998","vin":"2FTJW35G4NC","components":"FUEL SYSTEM, GASOLINE","summary":"DUAL REAR TIRE EXPOLDED AND SEVERED THE RUBBER FUEL FILL LINE TO THE FUEL TANKS AND IMMEDIATELY SET THE TRUCK ON FIRE.  TRUCK, TRAILER AND BOAT ALL BURNED.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":825177,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"07/08/1998","vin":"2FTJW36M3NC","components":"STEERING,SERVICE BRAKES, HYDRAULIC,POWER TRAIN","summary":"WHEN TRAVELING THE POWER ASSIST BELT CAME OFF, CAUSING LOSS OF POWER STEERING/POWER BRAKES AND LOSS OF VEHICLE CONTROL,  RESULTING IN A NEAR ACCIDENT.  CONSUMER HAS CONTACTED THE DEALER. DEALER HAS REPLACED PARTS. PLEASE PROVIDE ANY FURTHER DETAILS. *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":536248,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"05/28/1998","dateComplaintFiled":"06/03/1998","vin":"1FTJX25M3NK","components":"ENGINE AND ENGINE COOLING","summary":"DRIVE BELTS BROKE CAUSING LOSS OF STEERING AND BRAKING CONTROL ALMOST RESULTING IN VEHICLE ACCIDENTS ON TWO OCCASIONS, BELTS REPLACED FIVE TIMES.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":535767,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"05/04/1998","dateComplaintFiled":"05/20/1998","vin":"2FTJW35G6NC","components":"WHEELS","summary":"WHEEL LUG NUTS SHEARED OFF CAUSING WHEEL TO FALL OFF/DAMAGE TO VEHICLE.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":531390,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"02/13/1998","vin":"1FTJX35M7NK","components":"SUSPENSION","summary":"SUSPENSION VIBRATION, CAUSING LOSS OF CONTROL.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":528805,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"01/23/1998","vin":"2FTJW36G4NC","components":"SERVICE BRAKES, HYDRAULIC","summary":"BRAKES NOT STOPPING VEHICLE PROPERLY.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":528003,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"10/01/1995","dateComplaintFiled":"01/08/1998","vin":"2FTJW35M4NC","components":"STEERING","summary":"THE BRONZE BUSHING IN THE TENSIONER WORE TO THE POINT THAT THE TENSION BEARING SURFACE ALLOWED THE SERPENTINE BELT TO SLIP OFF THE TENSIONEER INTO THE FAN, WHICH DESTROYED THE BELT.  VEHICLE WAS LEFT WITH NO POWER STEERING OR POWER BRAKES.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":527553,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"12/26/1997","vin":"2FTJW35M4NC","components":"STEERING","summary":"BRONZE BUSHING IN THE TENSIONER WORE TO THE POINT THAT THE TENSION BEARING SURFACE ALLOWED THE SERPENTINE BELT TO SLIP OFF THE TENSIONER INTO THE FAN WHICH DESTROYED THE BELT MAKING IT DIFFICULT TO HANDLE WITHOUT POWER BRAKES OR STEERING.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":815387,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"07/08/1997","dateComplaintFiled":"08/08/1997","vin":"2FDHF37H0NC","components":"FUEL SYSTEM, GASOLINE","summary":"VEHICLE EXPERIENCING OVERFLOW FROM REAR TANK TO FRONT TANK AND BACK TO REAR TANK, CAUSING SPILLAGE. THIS OCCURS WHENEVER ENGINE IS RUNNING.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":810313,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"03/24/1997","dateComplaintFiled":"03/24/1997","vin":"","components":"SERVICE BRAKES, HYDRAULIC","summary":"ABS BRAKES, WHEN BRAKES ARE APPLIED, EXPERIENCED EXTENDED STOPPING DISTANCE, AND BRAKE PEDAL BECAME VERY SOFT.  IN FOR REPAIRS,  WILL PROVIDE REPAIR VOUCHER.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":810198,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"03/20/1997","vin":"","components":"STRUCTURE","summary":"FIREWALL IN AREA OF MASTER CYLINDER AND HYDRAULIC CLUTCH WELD FELL APART,  ALLOWING FIREWALL TO MOVE AROUND.   *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":513737,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"08/01/1996","dateComplaintFiled":"01/16/1997","vin":"1FDHF37M9NN","components":"POWER TRAIN","summary":"TRANSMISSION GEAR TRAIN SUPPORT BUSHING FAILED.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":509566,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"11/10/1994","dateComplaintFiled":"10/07/1996","vin":"1FTJX35M2NK","components":"SERVICE BRAKES, HYDRAULIC","summary":"BRAKE PEDAL PULSATES.","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":506330,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/27/1996","dateComplaintFiled":"07/12/1996","vin":"2FDKF38M3NC","components":"POWER TRAIN","summary":"CLUTCH PUSH ROD BECOMES DISCONNECTED ALLOWING TRUCK TO STAY IN GEAR.*SD","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":984365,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"05/10/1996","vin":"","components":"STEERING","summary":"THE STEERING TENSIONER IS WORN AND IS CAUSING THE SEPENTINE BELT TO FLY OFF AND STEERING LOSS. PLEASE DESCRIBE.      *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":984078,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"02/01/1996","dateComplaintFiled":"05/06/1996","vin":"2FAPP36X8MB","components":"SERVICE BRAKES, HYDRAULIC","summary":"PE96-005, REAR BRAKE FAILURE, ADJUSTER FELL OFF, WENT THROUGH THE DRUM, CAUSING A LOCKUP AND LOSS OF BRAKES.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":983444,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"04/24/1996","vin":"","components":"STEERING","summary":"WHILE DRIVING FRONT WHEELS VIBRATE EXCESSIVELY WHICH AFFECTS STEERING PROFICENCY. PLEASE DECRIBE DETAILS.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":504497,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"10/02/1994","dateComplaintFiled":"04/22/1996","vin":"1FDKE30GONM","components":"ELECTRICAL SYSTEM","summary":"NOTICED BURNING ODOR IN THE IGNITION SWITCH AREA (OTHER VEHICLE FROM 983267)>   *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":978153,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/01/1995","dateComplaintFiled":"01/24/1996","vin":"1FTJX35M3NK","components":"ENGINE AND ENGINE COOLING","summary":"SERPENTINE BELT BREAKS WHILE DRIVING, TOTAL LOSS OF POWER STEERING, POWER BRAKES AND OTHER SAFETY FEATURES.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":978153,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/01/1995","dateComplaintFiled":"01/24/1996","vin":"1FTJX35M3NK","components":"ENGINE AND ENGINE COOLING","summary":"SERPENTINE BELT BREAKS WHILE DRIVING, TOTAL LOSS OF POWER STEERING, POWER BRAKES AND OTHER SAFETY FEATURES.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":974857,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"11/13/1995","vin":"","components":"ELECTRICAL SYSTEM","summary":"FAN BELT GETS THROWN OFF AND MESSES UP THE STEERING AND ELECTRIC.  PLEASE DESCRIBE.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":974857,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"11/13/1995","vin":"","components":"ENGINE AND ENGINE COOLING","summary":"FAN BELT GETS THROWN OFF AND MESSES UP THE STEERING AND ELECTRIC.  PLEASE DESCRIBE.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":974857,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"11/13/1995","vin":"","components":"STEERING","summary":"FAN BELT GETS THROWN OFF AND MESSES UP THE STEERING AND ELECTRIC.  PLEASE DESCRIBE.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":973080,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"10/06/1995","vin":"2FTJW35M6NC","components":"SERVICE BRAKES, HYDRAULIC","summary":"THE PERFORMANCE OF THE BRAKE IS NOT THAT GOOD .  TT  *JB","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":972721,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"09/29/1995","dateComplaintFiled":"09/29/1995","vin":"2FTJW36M4NC","components":"POWER TRAIN","summary":"PREMATURE FAILURE OF THE CLUTCH ON VEHICLE WITH MANAUL TRANSMISSION, FIRST CLUTCH FAILED 18K MILES, SECOND FAILED 43, THIRD AT 50K MILES.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":971632,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":null,"dateComplaintFiled":"09/06/1995","vin":"2FTJW36M2NC","components":"SERVICE BRAKES, HYDRAULIC","summary":"HAD BRAKING SYSTEM REPLACED BECAUSE OF VIBRATION WHILE BRAKING.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":966657,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"06/08/1995","dateComplaintFiled":"06/12/1995","vin":"1FDKF37M8NN","components":"ENGINE AND ENGINE COOLING","summary":"THE MAIN DRIVE BELT BROKE WHILE ON A CALL.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960269,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"02/22/1994","dateComplaintFiled":"02/21/1995","vin":"2FTJW36M3PC","components":"ENGINE AND ENGINE COOLING","summary":"SINGLE SERPENTINE BELT CAUSES POWER STEERING TO BECOME INOPERATIVE.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960121,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"09/08/1994","dateComplaintFiled":"02/16/1995","vin":"1FTHF36M8NN","components":"SERVICE BRAKES, HYDRAULIC","summary":"WARPED FRONT BRAKE ROTORS/PADS, CAUSING VEHICLE TO VIBRATE UPON BRAKING.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960121,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"01/03/1994","dateComplaintFiled":"02/16/1995","vin":"1FTHF36M8NN","components":"ENGINE AND ENGINE COOLING","summary":"REPLACED TENSIONEER/IDLER BELT. *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960121,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"01/07/1994","dateComplaintFiled":"02/16/1995","vin":"1FTHF36M8NN","components":"SERVICE BRAKES, HYDRAULIC","summary":"REPLACED REAR BRAKE SHOES/DRUMS.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960121,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"03/10/1993","dateComplaintFiled":"02/16/1995","vin":"1FTHF36M8NN","components":"TIRES","summary":"EXCESSIVE WEAR OF FRONT TIRES.  *AK","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960060,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"02/11/1995","dateComplaintFiled":"02/15/1995","vin":"1FTJX35G9NK","components":"POWER TRAIN","summary":"REAR END CAME COMPLETELY OFF THE TRUCK, BECAUSE THE GREASE WAS NOT REACHING THE HUBS.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":960028,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"02/14/1995","dateComplaintFiled":"02/14/1995","vin":"1FTJX35MXNK","components":"PARKING BRAKE","summary":"EMERGENCY PARKING BRAKE PAWL DOES NOT PROPERLY LINE UP, ALLOWING FREE MOVEMENT OF VEHICLE. RECALL RELATED. PLEASE DESCRIBE DETAILS.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":958896,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"12/19/1994","dateComplaintFiled":"01/19/1995","vin":"1FTHF36M2NN","components":"ENGINE AND ENGINE COOLING","summary":"FAN BELT COMES OFF; CAUSING LOSS OF POWER STEERING/BRAKES; SNAPPED BOLT THAT HOLDS IDLE PULLEY.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":958896,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"12/19/1994","dateComplaintFiled":"01/19/1995","vin":"1FTHF36M2NN","components":"STEERING","summary":"FAN BELT COMES OFF; CAUSING LOSS OF POWER STEERING/BRAKES; SNAPPED BOLT THAT HOLDS IDLE PULLEY.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]},{"odiNumber":958896,"manufacturer":"Ford Motor Company","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"12/19/1994","dateComplaintFiled":"01/19/1995","vin":"1FTHF36M2NN","components":"SERVICE BRAKES, HYDRAULIC","summary":"FAN BELT COMES OFF; CAUSING LOSS OF POWER STEERING/BRAKES; SNAPPED BOLT THAT HOLDS IDLE PULLEY.  TT","products":[{"type":"Vehicle","productYear":"1992","productMake":"FORD","productModel":"F-350","manufacturer":"Ford Motor Company"}]}]}