{"count":3,"message":"Results returned successfully","results":[{"odiNumber":11778929,"manufacturer":"Forest River, Inc.","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"10/04/2024","dateComplaintFiled":"11/18/2026","vin":"4X4FCAL21DG","components":"STRUCTURE,UNKNOWN OR OTHER","summary":"2013 Forest River Cardinal 3450RL with Lippert frame. The bedroom slide appears lower on the right side, with significant cracking and separation at the lower right corner of the slide opening. Possible frame flex or structural movement. RV is stationary in Spring Hill, FL, and available for inspection.  I am concerned further structural movement could compromise the slide opening, sidewall, or frame and make towing unsafe. No dealer or independent inspection has confirmed the cause. Forest River has been contacted but has not physically inspected the current damage.  The RV had previous slide-seal failures and exterior wall delamination shortly after purchase in 2013. Forest River transported it to its factory for several months of repairs at its expense. I am requesting review of this potential structural safety issue.","products":[{"type":"Vehicle","productYear":"2013","productMake":"FOREST RIVER","productModel":"CARDINAL","manufacturer":"Forest River, Inc."}]},{"odiNumber":10957874,"manufacturer":"Forest River, Inc.","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"12/23/2016","dateComplaintFiled":"03/01/2017","vin":"4X4FCAL21DG","components":"STRUCTURE","summary":"TL* THE CONTACT OWNS A 2013 FOREST RIVER CARDINAL. THE CONTACT STATED THAT THE SEALS ON THE TOP AND SIDE OF THE CAMPER DETACHED DUE TO WATER. THE CONTACT MENTIONED THAT WATER WAS ENTERING THE CAMPER AND DAMAGED THE INTERIOR. THE CAMPER WAS TAKEN TO A DEALER WHERE IT WAS DIAGNOSED THAT THE SEALS NEEDED TO BE REPLACED. THE CAMPER WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE VIN AND FAILURE MILEAGE WERE NOT PROVIDED.  UPDATED 05/05/17*LJ  THE CONSUMER STATED THE MANUFACTURER OFFERED TO PAY FOR THE COST OF THE PARTS ONLY. UPDATED 09/22/2017*JS","products":[{"type":"Vehicle","productYear":"2013","productMake":"FOREST RIVER","productModel":"CARDINAL","manufacturer":"Forest River, Inc."}]},{"odiNumber":10743444,"manufacturer":"Forest River, Inc.","crash":false,"fire":false,"numberOfInjuries":0,"numberOfDeaths":0,"dateOfIncident":"07/22/2015","dateComplaintFiled":"07/25/2015","vin":"4X4FCAL20CG","components":"ELECTRICAL SYSTEM","summary":"PRIOR TO LEAVING FOR A TRIP I PLUGGED OUR CARDINAL 3550RL IN TO AN AC OUTLET TO RUN THE FRIDGE. THE MORNING OF OUR DEPARTURE I FOUND THAT THE 2 REAR SLIDE ROOMS HAD DEPLOYED OVERNIGHT ON THEIR OWN AND WOULD NOT RETRACT. THE SLIDE ROOM PUMP HAD RUN ALL NIGHT AND BURNED THE PUMP OUT SO BADLY THAT WE COULD NOT MANUALLY RETRACT THE ROOMS OR THE LANDING GEAR. THE TRANSMISSION FLUID WAS SCORCHED AND COULD HAVE CAUGHT FIRE DURING THE NIGHT ACCORDING TO OUR TECH. THIS COULD HAVE BEEN CATASTROPHIC GIVEN THE RIGS LOCATION . I WOULD HAVE LOST 2 TRUCKS A BOAT AND 2 PETS ALONG WITH THE TRAILER.UPON FURTHER INVESTIGATION IT WAS FOUND THAT 2 WIRE SPADES IN THE INTERIOR CONTROL PANEL HAD VIBRATED OFF AND WERE VERY LOOSE FITTING CAUSING A SHORT. IMAGINE THIS HAPPENING WHILE YOU ARE ON THE ROAD AND THE ROOMS DEPLOY IN TRAFFIC! THERE WERE NO INLINE FUSES, BREAKERS OR OTHER FAIL-SAFES TO PREVENT THIS FROM HAPPENING. IN OUR OPINION THIS WAS CAUSED BY SLOPPY WORKMANSHIP AND POOR ENGINEERING DESIGN. I HAVE CONTACTED THE MANUFACTURER BUT WAS STONEWALLED AND NEVER GOT A CALL BACK THAT WAS REQUESTED FROM A MANAGER. CONTACT - FOREST RIVER, ELKHART IN 573-533-5934  ## VIN FAILED ## 2012 FOREST RIVER CARDINAL 3550 RL ##","products":[{"type":"Vehicle","productYear":"2013","productMake":"FOREST RIVER","productModel":"CARDINAL","manufacturer":"Forest River, Inc."}]}]}