{"Count":3,"Message":"Results returned successfully","results":[{"Manufacturer":"GENERAL MOTORS CORP.","NHTSACampaignNumber":"93V094000","parkIt":false,"parkOutSide":false,"overTheAirUpdate":false,"ReportReceivedDate":"25/05/1993","Component":"ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES","PotentialNumberofUnitsAffected":14459,"Summary":"THE POSITIVE BATTERY CABLE TERMINAL AT THE STARTER SOLENOID MAY BE FORMED INCORRECTLY. INCORRECTLY FORMED TERMINALS CAN CONTACT THE STARTER SOLENOID HOUSING AND CAUSE AN ELECTRIC SHORT CIRCUIT.","Consequence":"AN ELECTRICAL SHORT CIRCUIT BETWEEN THE BATTERY CABLE ANDTHE STARTER HOUSING CAN RESULT IN AN UNDERHOOD FIRE.","Remedy":"INSPECT AND, IF NECESSARY, ADJUST THE CLEARANCE BETWEEN THE POSITIVE BATTERY CABLE TERMINAL SO THAT IT DOES NOT CONTACT THE STARTER SOLENOID HOUSING.","Notes":"SYSTEM: ELECTRICAL.VEHICLE DESCRIPTION: SEDANS, COUPES, AND STATION WAGONS EQUIPPED WITH TWIN CAM16 VALVE ENGINES.","ModelYear":"1993","Make":"SATURN","Model":"SC1"},{"Manufacturer":"GENERAL MOTORS CORP.","NHTSACampaignNumber":"93V094000","parkIt":false,"parkOutSide":false,"overTheAirUpdate":false,"ReportReceivedDate":"25/05/1993","Component":"ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES","PotentialNumberofUnitsAffected":14459,"Summary":"THE POSITIVE BATTERY CABLE TERMINAL AT THE STARTER SOLENOID MAY BE FORMED INCORRECTLY. INCORRECTLY FORMED TERMINALS CAN CONTACT THE STARTER SOLENOID HOUSING AND CAUSE AN ELECTRIC SHORT CIRCUIT.","Consequence":"AN ELECTRICAL SHORT CIRCUIT BETWEEN THE BATTERY CABLE ANDTHE STARTER HOUSING CAN RESULT IN AN UNDERHOOD FIRE.","Remedy":"INSPECT AND, IF NECESSARY, ADJUST THE CLEARANCE BETWEEN THE POSITIVE BATTERY CABLE TERMINAL SO THAT IT DOES NOT CONTACT THE STARTER SOLENOID HOUSING.","Notes":"SYSTEM: ELECTRICAL.VEHICLE DESCRIPTION: SEDANS, COUPES, AND STATION WAGONS EQUIPPED WITH TWIN CAM16 VALVE ENGINES.","ModelYear":"1993","Make":"SATURN","Model":"SL"},{"Manufacturer":"GENERAL MOTORS CORP.","NHTSACampaignNumber":"93V094000","parkIt":false,"parkOutSide":false,"overTheAirUpdate":false,"ReportReceivedDate":"25/05/1993","Component":"ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES","PotentialNumberofUnitsAffected":14459,"Summary":"THE POSITIVE BATTERY CABLE TERMINAL AT THE STARTER SOLENOID MAY BE FORMED INCORRECTLY. INCORRECTLY FORMED TERMINALS CAN CONTACT THE STARTER SOLENOID HOUSING AND CAUSE AN ELECTRIC SHORT CIRCUIT.","Consequence":"AN ELECTRICAL SHORT CIRCUIT BETWEEN THE BATTERY CABLE ANDTHE STARTER HOUSING CAN RESULT IN AN UNDERHOOD FIRE.","Remedy":"INSPECT AND, IF NECESSARY, ADJUST THE CLEARANCE BETWEEN THE POSITIVE BATTERY CABLE TERMINAL SO THAT IT DOES NOT CONTACT THE STARTER SOLENOID HOUSING.","Notes":"SYSTEM: ELECTRICAL.VEHICLE DESCRIPTION: SEDANS, COUPES, AND STATION WAGONS EQUIPPED WITH TWIN CAM16 VALVE ENGINES.","ModelYear":"1993","Make":"SATURN","Model":"SW"}]}